- Load Flow Analysis Software
- Free Load Flow Software
- Open Source Load Flow Software
- Load Flow Analysis Using Etap Software
'Flow puts real power in the hands of regular users. Collecting Twitter data used to require development skills. Now, we can use a flow to key in on a specific term, have those tweets delivered to a SQL Azure database, and run it through Power BI for near real-time analysis.' Load Flow Software. Load flow analysis software performs power flow analysis and voltage drop calculations with accurate and reliable results. Built-in features like automatic equipment evaluation, alerts and warnings summary, load flow result analyzer, and intelligent graphics make it the most efficient electrical power flow analysis tool available. The Power Flow module software is the power flow analysis module of the CYME power engineering software for the analysis of three-phase electric power networks. It is equipped with powerful analytical options and alternative solution techniques.
Flowchart Maker is a flowchart design app for Windows, whcih is also compatible with Mac OS X and Linux systems. It provides you with a drag-and-drop interface and a large variety of built-in symbols for flowchart, and data flow diagram creation.
Microsoft Visio system requirements:
Component Minimum Requirement
Memory 2 GB RAM
Display 1280 x 800 screen resolution
Graphics Graphics hardware acceleration requires a DirectX 10 graphics card.
Operating system Windows 7 SP1 to Windows 10, 32-bit or 64-bit OS only
Internet access. Fees may apply.
Microsoft account
Some features may require additional hardware or services, for example:
- Microsoft SharePoint Server 2010, SharePoint Server 2013, Microsoft SharePoint Online, or Microsoft OneDrive for Business is required for coauthoring.
Visio Online Plan 1, which includes Visio Online and 2GB of OneDrive storage, enables users to create and share simple diagrams in their favorite browser. It’s best for basic diagramming needs.
Visio Online Plan 2 includes Visio desktop, Visio Online, and 2GB of OneDrive storage, making it our most powerful diagramming suite. It’s best for professional diagramming needs. Visio desktop comes with a robust library of built-in and third-party templates and shapes, as well as integrated collaboration tools. It also receives all latest feature releases and enables you to connect diagrams to live data. Plus, you can store and share your diagrams online, then use your favorite browser to view and edit them through Visio Online. Both Visio and Visio Online offer collaboration through in-app comments.
For more details on how to buy a Visio Online subscription, visit our plans and pricing page.
Visio Online Plan 2, available as a subscription, includes the all same capabilities as Visio Professional 2016, as well as cloud-only features like Visio Visual in Power BI, Data Visualizer through Excel, and Database Reverse Engineering (DBRE). Enhanced support for AutoCAD drawings and more templates, stencils, and shapes are also only available in Plan 2. Plus, Plan 2 allows each user to install Visio on up to five PCs running Windows 10, Windows 8, or Windows 7. It automatically installs the latest security updates and receives all feature releases for the duration of the subscription. Visio Online Plan 1 with 2GB OneDrive storage is also included.
For information on how to license Visio, please visit our licensing page.
Yes! Most Office 365 customers can view their Visio diagrams in Teams. Those with a Visio Online plan subscription can also edit diagrams directly in Teams. You can learn more about Visio in Teams here. Please note, Teams is sold separately from Visio.
Power BI users can download the Visio Visual here. All users can view a Visio Visual report in Power BI and embed file links, but only those with a Visio Online license can edit the visual. Read our Tech Community blog post to learn more about Visio Visual for Power BI.
Visio currently supports multiple data sources, including Microsoft Excel, Microsoft Excel Services, Active Directory, Microsoft SQL Server, Microsoft SQL Azure, and Microsoft SharePoint Lists and Business Connectivity Services.
Data-linking is only available through Visio, although you can view data-linked diagrams using Visio Online.
Visio shares many of the same security features as Microsoft Office apps. These include Information Rights Management (IRM) to set file access permissions and built-in data loss prevention (DLP) and multi-factor authentication (MFA) to help prevent data leaks. Likewise, Visio Online inherits all enterprise-grade security, privacy, and compliance features available through the Microsoft Cloud.
Yes. Any Visio Online diagram can be accessed, created, edited, and shared using your preferred mobile browser. There is also a native Visio Viewer app for iOS devices. You can only view diagrams using the app; editing capabilities are not available.
There is no Visio client version for Mac. Instead, you can use Visio Online to diagram in your browser.
Visio Professional 2016, Visio Standard 2016, and Visio Online keep the same XML-based file format introduced in 2013. Early versions of Visio may not recognize this format. You can save files that were created in Visio 2016 or Visio Online in the Visio 2003–2010 Drawing (VSD) format, which earlier versions of Visio can open. To do this, go to the File menu and choose Save As. Once a location has been selected, change the Save as type to Visio 2003–2010 Drawing.
Some features from earlier versions of Visio have been disabled for compatibility in Visio 2016. Converting the old file to the new file format will enable all features. To convert a Visio 2003–2010 drawing, go to the Filemenu, select Info, then Convert.
To ask questions, please connect with us on the Visio Answers or the Visio MSDN forums. You can also email us at [email protected] and send feedback through UserVoice.
In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as voltages, voltage angles, real power and reactive power. It analyzes the power systems in normal steady-state operation.
Power-flow or load-flow studies are important for planning future expansion of power systems as well as in determining the best operation of existing systems. The principal information obtained from the power-flow study is the magnitude and phase angle of the voltage at each bus, and the real and reactive power flowing in each line.
Commercial power systems are usually too complex to allow for hand solution of the power flow. Special purpose network analyzers were built between 1929 and the early 1960s to provide laboratory-scale physical models of power systems. Large-scale digital computers replaced the analog methods with numerical solutions.
In addition to a power-flow study, computer programs perform related calculations such as short-circuit fault analysis, stability studies (transient and steady-state), unit commitment and economic dispatch.[1] In particular, some programs use linear programming to find the optimal power flow, the conditions which give the lowest cost per kilowatt hour delivered.
A load flow study is especially valuable for a system with multiple load centers, such as a refinery complex. The power flow study is an analysis of the system’s capability to adequately supply the connected load. The total system losses, as well as individual line losses, also are tabulated. Transformer tap positions are selected to ensure the correct voltage at critical locations such as motor control centers. Performing a load flow study on an existing system provides insight and recommendations as to the system operation and optimization of control settings to obtain maximum capacity while minimizing the operating costs. The results of such an analysis are in terms of active power, reactive power, magnitude and phase angle. Furthermore, power-flow computations are crucial for optimal operations of groups of generating units.
In term of its approach to uncertainties, load flow study can be divided to deterministic load flow and uncertainty-concerned load flow. Deterministic load flow study does not take into account the uncertainties arise from both power generations and load behaviors. To take the uncertainties into consideration, there are several approaches that has been used such as probabilistic, possibilistic, information gap decision theory, robust optimization, and interval analysis[2].
The Open Energy Modelling Initiative promotes open source load-flow models and other types of energy system models.
Model[edit]
An alternating current power-flow model is a model used in electrical engineering to analyze power grids. It provides a nonlinear system which describes the energy flow through each transmission line. The problem is non-linear because the power flow into load impedances is a function of the square of the applied voltages. Due to nonlinearity, in many cases the analysis of large network via AC power-flow model is not feasible, and a linear (but less accurate) DC power-flow model is used instead.
Usually analysis of a three-phase system is simplified by assuming balanced loading of all three phases. Steady-state operation is assumed, with no transient changes in power flow or voltage due to load or generation changes. The system frequency is also assumed to be constant. A further simplification is to use the per-unit system to represent all voltages, power flows, and impedances, scaling the actual target system values to some convenient base. A system one-line diagram is the basis to build a mathematical model of the generators, loads, buses, and transmission lines of the system, and their electrical impedances and ratings.
Power-flow problem formulation[edit]
The goal of a power-flow study is to obtain complete voltages angle and magnitude information for each bus in a power system for specified load and generator real power and voltage conditions.[3] Once this information is known, real and reactive power flow on each branch as well as generator reactive power output can be analytically determined. Due to the nonlinear nature of this problem, numerical methods are employed to obtain a solution that is within an acceptable tolerance.
The solution to the power-flow problem begins with identifying the known and unknown variables in the system. The known and unknown variables are dependent on the type of bus. A bus without any generators connected to it is called a Load Bus. With one exception, a bus with at least one generator connected to it is called a Generator Bus. The exception is one arbitrarily-selected bus that has a generator. This bus is referred to as the slack bus.
In the power-flow problem, it is assumed that the real power PD and reactive power QD at each Load Bus are known. For this reason, Load Buses are also known as PQ Buses. For Generator Buses, it is assumed that the real power generated PG and the voltage magnitude |V| is known. For the Slack Bus, it is assumed that the voltage magnitude |V| and voltage phase Θ are known. Therefore, for each Load Bus, both the voltage magnitude and angle are unknown and must be solved for; for each Generator Bus, the voltage angle must be solved for; there are no variables that must be solved for the Slack Bus. In a system with N buses and R generators, there are then unknowns.
In order to solve for the unknowns, there must be equations that do not introduce any new unknown variables. The possible equations to use are power balance equations, which can be written for real and reactive power for each bus.The real power balance equation is:
where is the net active power injected at bus i, is the real part of the element in the bus admittance matrix YBUS corresponding to the row and column, is the imaginary part of the element in the YBUS corresponding to the row and column and is the difference in voltage angle between the and buses (). The reactive power balance equation is:
where is the net reactive power injected at bus i.
Load Flow Analysis Software
Equations included are the real and reactive power balance equations for each Load Bus and the real power balance equation for each Generator Bus. Only the real power balance equation is written for a Generator Bus because the net reactive power injected is assumed to be unknown and therefore including the reactive power balance equation would result in an additional unknown variable. For similar reasons, there are no equations written for the Slack Bus.
In many transmission systems, the voltage angles are usually relatively small. There is thus a strong coupling between real power and voltage angle, and between reactive power and voltage magnitude, while the coupling between real power and voltage magnitude, as well as reactive power and voltage angle, is weak. As a result, real power is usually transmitted from the bus with higher voltage angle to the bus with lower voltage angle, and reactive power is usually transmitted from the bus with higher voltage magnitude to the bus with lower voltage magnitude. However, this approximation does not hold when the voltage angle is very large.[4]
Newton–Raphson solution method[edit]
There are several different methods of solving the resulting nonlinear system of equations. The most popular is known as the Newton–Raphson method. This method begins with initial guesses of all unknown variables (voltage magnitude and angles at Load Buses and voltage angles at Generator Buses). Next, a Taylor Series is written, with the higher order terms ignored, for each of the power balance equations included in the system of equations .The result is a linear system of equations that can be expressed as:
where and are called the mismatch equations:
and is a matrix of partial derivatives known as a Jacobian:.
The linearized system of equations is solved to determine the next guess (m + 1) of voltage magnitude and angles based on:
The process continues until a stopping condition is met. A common stopping condition is to terminate if the norm of the mismatch equations is below a specified tolerance.
A rough outline of solution of the power-flow problem is:
- Make an initial guess of all unknown voltage magnitudes and angles. It is common to use a 'flat start' in which all voltage angles are set to zero and all voltage magnitudes are set to 1.0 p.u.
- Solve the power balance equations using the most recent voltage angle and magnitude values.
- Linearize the system around the most recent voltage angle and magnitude values
- Solve for the change in voltage angle and magnitude
- Update the voltage magnitude and angles
- Check the stopping conditions, if met then terminate, else go to step 2.
Free Load Flow Software
Other power-flow methods[edit]
- Gauss–Seidel method: This is the earliest devised method. It shows slower rates of convergence compared to other iterative methods, but it uses very little memory and does not need to solve a matrix system.
- Fast-decoupled-load-flow method is a variation on Newton-Raphson that exploits the approximate decoupling of active and reactive flows in well-behaved power networks, and additionally fixes the value of the Jacobian during the iteration in order to avoid costly matrix decompositions. Also referred to as 'fixed-slope, decoupled NR'. Within the algorithm, the Jacobian matrix gets inverted only once, and there are three assumptions. Firstly, the conductance between the buses is zero. Secondly, the magnitude of the bus voltage is one per unit. Thirdly, the sine of phases between buses is zero. Fast decoupled load flow can return the answer within seconds whereas the Newton Raphson method takes much longer. This is useful for real-time management of power grids.[5]
- Holomorphic embedding load flow method: A recently developed method based on advanced techniques of complex analysis. It is direct and guarantees the calculation of the correct (operative) branch, out of the multiple solutions present in the power flow equations.
Open Source Load Flow Software
References[edit]
- ^Low, S. H. (2013). 'Convex relaxation of optimal power flow: A tutorial'. 2013 IREP Symposium Bulk Power System Dynamics and Control - IX Optimization, Security and Control of the Emerging Power Grid. pp. 1–06. doi:10.1109/IREP.2013.6629391. ISBN978-1-4799-0199-9.
- ^Aien, Morteza; Hajebrahimi, Ali; Fotuhi-Firuzabad, Mahmud (2016). 'A comprehensive review on uncertainty modeling techniques in power system studies'. Renewable and Sustainable Energy Reviews. 57: 1077–1089. doi:10.1016/j.rser.2015.12.070.
- ^Grainger, J.; Stevenson, W. (1994). Power System Analysis. New York: McGraw–Hill. ISBN0-07-061293-5.
- ^Andersson, G: Lectures on Modelling and Analysis of Electric Power SystemsArchived 2017-02-15 at the Wayback Machine
- ^Stott, B.; Alsac, O. (May 1974). 'Fast Decoupled Load Flow'. IEEE Transactions on Power Apparatus and Systems. PAS-93 (3): 859–869. doi:10.1109/tpas.1974.293985. ISSN0018-9510.
Load Flow Analysis Using Etap Software